Dec 22, 2025

Fiber Optic Cable Tib -Reel test: Cov txheej txheem, OTDR Test, thiab Kev Tswj Xyuas Zoo

Tso lus

Vim li cas Ib Leeg -Reel Kev Tshawb Fawb Kev Sib Txuas Lus Optical Cables Yuav Tsum Tau?

Ib leeg -reel tshuaj xyuas ntawm kev sib txuas lus kho qhov muag cables yog ib qho tseem ceeb ntawm kev tswj kom zoo ua ntej kev tsim kho. Nws lub hom phiaj yog txhawm rau txheeb xyuas cov tsos mob, geometric tsis, thiab kho qhov muag kis tau tus mob ntawm kev xa khoom kho qhov muag cables ua ntej kev teeb tsa, txhawm rau txheeb xyuas qhov muaj peev xwm zais qhov tsis xws luag tshwm sim los ntawm kev tsim khoom, kev thauj mus los, kev thauj khoom thiab thauj khoom, lossis kev khaws cia thaum ntxov, thiab tiv thaiv cov teeb meem los ntawm kev nthuav tawm tom qab kev teeb tsa cable, uas tuaj yeem ua rau kev lag luam rov ua haujlwm, poob sijhawm qeeb, thiab kev lag luam.

Thaum kev sib txuas lus kho qhov muag cables tau teeb tsa lawm -tshwj xeeb tshaj yog tom qab kev teeb tsa dav hlau, kev faus ncaj qha, lossis kev teeb tsa duct - tus nqi kho thiab hloov pauv yog qhov siab heev. Yog li ntawd, ib leeg -reel tshuaj xyuas yog ib qho kev ntsuas tseem ceeb los hloov kev tswj hwm kev pheej hmoo rau pem hauv ntej thiab txheeb xyuas thaj tsam ntawm lub luag haujlwm ua ntej.

Cov teeb meem uas yuav tshwm sim yog ib leeg -Reel Inspection tsis ua

  • Nkaum fiber ntau so lossis micro- tawg tsuas yog tom qab kev teeb tsa

Thaum lub sij hawm kev thauj mus los thiab tuav, kho qhov muag cables tej zaum yuav raug cuam tshuam, compression, los yog dabtsi yog khoov, ua rau kev nyuaj siab concentration thiab tsim micro- tawg nyob rau hauv cov fibers. Cov teeb meem zoo li no tsis yooj yim pom los ntawm kev soj ntsuam pom ib leeg, tab sis tuaj yeem txhim kho mus rau hauv fiber ntau tawg nyob rau hauv kev teeb tsa nruj lossis kev ua haujlwm ntev -, ua rau kev sib txuas lus cuam tshuam.

  • Tsis txaus qhov tseeb cable ntev, yuam kev hloov mus rau qhov chaw repeater lossis splicing schemes

Yog tias qhov ntev reel tsis raug txheeb xyuas thaum ib zaug -reel tshuaj xyuas, qhov ntev tsis txaus tsuas yog nrhiav tau thaum lub sijhawm teeb tsa, uas yuav xav tau ib ntus ntxiv splices lossis hloov txoj hauv kev. Qhov no tsis yog tsuas yog cuam tshuam rau kev ua haujlwm ntawm qhov kev ua tau zoo tab sis kuj tseem tuaj yeem cuam tshuam qhov kev tsim nyog ntawm tus qauv tsim qauv.

  • Cov kab mob OTDR txawv txav nrog lub luag haujlwm tsis meej

Yog tias tsis muaj ib qho -reel OTDR kuaj ua ntej kev teeb tsa, qhov txawv txav xws li kev txo qis ntau dhau los yog cov fiber ntau tawg tom qab ua rau nws nyuaj rau kev txiav txim siab seb qhov teeb meem puas yog los ntawm kev tsim khoom, kev puas tsuaj, lossis kev ua haujlwm ib puag ncig, ua rau lub luag haujlwm tsis meej.

  • Nyuaj hauv kev thov tom qab kev tsim kho tiav

Yog tsis muaj cov ntaub ntawv kuaj ua ntej ua ntej - cov ntaub ntawv kev teeb tsa ua pov thawj, feem ntau nyuaj rau kev lees paub lub luag haujlwm zoo lossis ua ntaub ntawv thov tawm tsam cov neeg muab khoom lossis cov neeg tsim kho.

General Requirements for Single -Reel Inspection

Kev tshuaj xyuas qhov tshwm sim

Tshawb xyuas seb lub hnab ntim khoom puas puas lawm, thiab qhib lub reel los tshuaj xyuas seb lub cable sheath puas pom muaj kev puas tsuaj los yog xoob strands, thiab seb lub cable kawg sealing puas zoo lawm. Txhua qhov kev puas tsuaj yuav tsum tau sau tseg kom ntxaws los ntawm cov duab lossis cov yeeb yaj kiab.

Txheej txheem

Txheeb xyuas cov duab kos, tsim cov ntaub ntawv, thiab cov ntawv cog lus kom nkag siab txog cov kev qhia tshwj xeeb xws li hom cable thiab kev ua haujlwm yuav tsum tau ua.

Txheeb xyuas cov ntawv pov thawj Hoobkas ntawm kev ua raws, Hoobkasdaim ntawv xeem, thiab cov ntaub ntawv ntsig txog rau txhua tus xa khoom xa tuaj.

Npaj cov cuab yeej ntsuas tsim nyog, cov hlua ntsuas, thiab cov ntaub ntawv teev tseg nrog rau qhov tsim nyogfiber optic cable test khoom.

Siv cov ntaub ntawv tshuaj ntsuam xyuas tus qauv los sau rau ntawm -site ib leeg-reel unpacking inspecting, txheeb xyuas tag nrho cov ntaub ntawv xa tawm, thiab kos npe kom meej rau tus lej xov tooj, qhov kawg xaiv, qhov ntev, hom, thiab cov phiaj xwm kev teeb tsa ntawm cable reel.

Tom qab kev soj ntsuam dhau lawm, tam sim ntawd rov ntim cov ntim, rov ua dua thiab ruaj ntseg cable xaus, rov txuas cov hlua tiv thaiv, thiab muab cov hlua tso rau hauv qhov chaw ruaj ntseg.

Cov kev ceev faj

Yog tias muaj teeb meem zoo lossis tsis yog - ua raws li cov qauv tsim lossis daim ntawv cog lus tau pom thaum kuaj xyuas, cov ntaub ntawv cuam tshuam yuav tsum tau ua tam sim los ntawm cov duab thiab cov ntaub ntawv sau. Cov cables zoo li no yuav tsum tsis txhob siv rau hauv qhov project thiab tus neeg muag khoom yuav tsum tau hu rau kev tuav.

Tib -Reel Optical Attenuation Measurement

Kev Xav Tau

Tib -reelattenuationkuaj fiber ntau optic cableyog ua los xyuas kom meej qhov ntev ntawm fiber ntau, attenuation, thiab lwm yam kis tau tus yam ntxwv ntawm xa optical cables.

Kev ntsuas cov cuab yeej nrog kev ua haujlwm siab thiab raug yuav tsum raug xaiv thiab ntsuas kom raug.

Cov txheej txheem kuajyuav tsum standardized. Rau ntawm -site ib leeg-reel kuaj, tsis yog- txoj kev puas tsuaj raug pom zoo, feem ntau siv txoj kev ntsuas backscattering pom zoo los ntawm ITU-T (International Telecommunication Union - Telecommunication Standardization Sector).

Ib tug kws saib xyuas kev txawj ntse uas muaj kev paub txog kev ua tau zoo thiab muaj peev xwm txheeb xyuas yuav tsum raug xaiv los qhia kev ua haujlwm thiab tshuaj xyuas thiab daws teeb meem. Cov neeg ua haujlwm kuaj yuav tsum muajOptical fiber cable kuajkev txawj ntse.

Kev ntsuas ntsuas

Ib leeg -reel optical attenuation testing feem ntau siv txoj kev backscattering. Txoj kev backscattering, tseem hu ua tusOTDR(Optical Time Domain Reflectometer), siv lub teeb backscattered los ntsuas fiber ntau attenuation. Nws yog ib qho uas tsis yog -kev puas tsuaj, ib qho - txoj kev ntsuas qhov kawg uas muaj qhov raug siab, kev ua haujlwm yooj yim, thiab kev ua haujlwm siab, ua rau nws tsim nyog rau kev sim teb.

Thaum lub sij hawm sim, ib tug coupler yog siv los txuas cov tub ntxhais fiber ntau ntawm ib leeg -reel optical cable rau OTDR. Hauv ib zaug -reel attenuation testing of power communication optical cables, the wavelength setting is generally 1550 nm. Kev ntsuas kev ntsuas tau pom hauv daim duab 2-4.

 

Schematic diagram of the backscattering method for single-reel optical cable testing

Daim duab 2-4Schematic daim duab ntawm txoj kev backscattering rau ib zaug -reel optical cable kuaj

 

Vim tias muaj qhov ntsuas qhov chaw tuag hauv OTDR cov cuab yeej, cov ntsiab lus ntawm cov xwm txheej yuav ploj mus lossis cov txiaj ntsig attenuation yuav tshwm sim ntau dhau. Yog li ntawd, 1-2 km tso tawm fiber ntau tuaj yeem muab tso rau ntawm qhov ntsuas thiab cov fiber ntau nyob rau hauv kev sim ntawm lub coupler kom tau txais kev ntsuas qhov tseeb dua.

Kev ntsuas ntsuas ntsuas

Txoj kev backscattering muab backscattering kab nkhaus, fiber ntau ntev, thiab fiber ntau attenuation tshwm sim ib txhij. Thaum tshuaj xyuaskuaj fiber ntau optic cableCov txiaj ntsig, kev saib xyuas yuav tsum tau them rau tus cursor positioning. Qhov pib taw tes ntawm qhov ntsuas reel ntev yuav tsum tau teem caij rau qhov kawg ntawm cov kauj ruam ntawm kev xa tawm fiber ntau, thiab qhov kawg taw tes yuav tsum tau teeb tsa ua ntej lub davhlau ya nyob twg xav txog ncov, raws li qhia hauv daim duab 2-6.

Results of the backward measurement method

Daim duab 2-6: Cov txiaj ntsig ntawm kev ntsuas rov qab

 

Thaum fiber ntau zoo, lub backscattering nkhaus yog uniform thiab txoj kab nqes yog maj mam. Qhov ntsuas nkhaus yuav tsum tsis muaj cov kauj ruam-zoo li tee, txoj kab nqes ntau dhau, tsis yog-Fresnel reflection point (fiber micro-cracks), lossis tsis yog-terminal reflection peaks (break point). Cov qhabnias xeem yuav tsum tau sau tseg siv cov ntaub ntawv sau tseg.

Kev txiav txim siab ntawm "Cov nqes siab tshaj"

Nyob rau hauv lub wavelength ntawm 1550 nm, qhov nruab nrab attenuation ntawm ib leeg - hom optical fiber feem ntau yuav tsum tsis pub tshaj 0.22–0.25 dB/km. Thaum ntsuas qhov ntsuas tau siab dua li qhov ntau, thiab qhov ntsuas qhov ntsuas qhov ntsuas tsis raug tau raug txiav tawm, cov tub ntxhais fiber ntau yuav raug txiav txim ua ntej kom muaj qhov tsis zoo.

Kev tsis lees txais tam sim lossis rov sim dua?

Thaum kuaj cov qhabnias ze rau qhov txwv lossis cov xwm txheej tsis txaus ntseeg tau pom, rov kuaj dua yuav tsum ua ntej. Yog tias tsim nyog, mem tes dav, lub sij hawm nruab nrab, los yog lub tso tawm fiber ntau yuav tsum tau kho ua ntej rov sim dua.

Fibers uas tseem ua tsis tau raws li qhov yuav tsum tau ua tom qab rov kuaj dua yuav tsum tau muab cais ua cov fibers uas tsis yog -raws li cov fibers.

Tag nrho -Reel Rejection los yog Ib Leeg-Fiber Handling?

Thaum qhov txawv txav tsuas yog txwv rau ib leeg fibers cores, "ib zaug-fiber rejection" txoj cai yuav raug siv, thiab cov fibers uas tseem tshuav yuav raug siv ntxiv tom qab kev pom zoo ntawm kev ua raws.

Thaum muaj ntau cov fibers nyob rau hauv tib lub reel pom qhov txawv txav, los yog thaum qhov txawv txav qhia tau hais tias ib tug systematic tis, tag nrho cov reel yuav tsum tau tsom mus rau re{0}} ntsuam xyuas, thiab yog hais tias tsim nyog, yuav txiav txim raws li tsis yog -conforming.

 

FAQ

Q: Dab tsi yog qhov txawv ntawm OTDR kuaj thiab kuaj pom?

A: Kev kuaj pom pom tsuas yog kuaj xyuas sab nraud thiab ntim khoom. Kev kuaj OTDR yog ib qho uas tsis yog -txoj kev puas tsuaj uas ntsuas qhov zoo ntawm fiber ntau, kuaj pom micro- tawg, txheeb xyuas qhov ntev, thiab ntsuas qhov txo qis - teeb meem tsis pom qhov muag tab sis tseem ceeb rau kev ua haujlwm.

Q: Yuav ua li cas kuaj cov ntaub ntawv pov thawj?

A: Siv cov ntaub ntawv sau tseg rau hauv cov ntaub ntawv: tus lej xov tooj, kev tsim fiber ntau, ntsuas qhov ntev, qhov txo qis, OTDR kab, thiab ib qho kev pom txawv txav. Txuag tag nrho cov ntaub ntawv xeem thiab cov duab - cov ntaub ntawv no tseem ceeb heev rau kev lees paub thiab kev lav phib xaub.

Q: Dab tsi yog qhov kev xav ntawm qhov kawg ntawm OTDR kab qhia?

A: Lub davhlau ya nyob twg rov qab ncov (Fresnel reflection) qhia txog lub cev kawg ntawm cov fiber ntau. Thaum txheeb xyuas cov txiaj ntsig, qhov taw qhia tus cursor yuav tsum nres ua ntej lub ncov no, tsis yog ntawm nws, kom tau txais qhov tseeb ntev thiab ntsuas qhov ntsuas. Reflection peaks nyob rau hauv nruab nrab ntawm ib tug kab yuav qhia tau tias so los yog tsis zoo connectors.

Q: Vim li cas kuaj ntawm 1550nm wavelength tshwj xeeb?

A: Lub 1550nm wavelength yog tus qauv rau ib zaug - hom fiber ntau kuaj vim: (1) nws muaj qis attenuation tshaj 1310nm nyob rau hauv qhov kev ncua deb, (2) nws rhiab heev rau micro- khoov thiab kev ntxhov siab, ua kom nws zoo dua rau kev kuaj pom qhov tsis xws luag, thiab (3) nws sawv cev rau qhov tsis zoo ntawm cov ntaub ntawv pov thawj.{7}

Q: Kuv yuav ua li cas thiaj paub qhov txawv ntawm qhov tawg ntawm fiber ntau thiab kev sib txuas tsis zoo ntawm OTDR kab?

A: Ib qho kev tawg fiber ntau qhia tau hais tias qhov poob tam sim ntawd tsis muaj qhov xav txog qhov siab tom qab. Ib qho kev sib txuas tsis zoo qhia tau hais tias ib kauj ruam - nqes nrog qhov kev xav rov qab, thiab cov kab txuas ntxiv dhau mus. Micro- tawg tshwm li tsis yog- Fresnel cov ntsiab lus xav txog (cov pob me me tsis muaj qhov poob loj).

Q: Cov xwm txheej dab tsi cuam tshuam rau ib leeg -reel xeem raug?

A: Kub hloov pauv, av noo, thiab kev co tuaj yeem cuam tshuam cov txiaj ntsig. Kuaj nyob rau hauv qhov chaw ruaj khov (15-25℃). Tsis txhob sim tam sim ntawd tom qab tsiv reels los ntawm qhov txias cia - tso cai rau qhov kub thiab txias stabilization. Khaws cov khoom sib txuas thaum tsis kuaj kom tsis txhob muaj plua plav thiab ya raws.

 

Xa kev nug